Stair Calculator: Rise, Run and Risers

Enter the height from finished floor to finished floor and a going. The calculator picks the number of risers, works out the riser height, the run and the angle, and checks them against the NCC limits for houses: a riser of 115 to 190 mm, a going of 240 to 355 mm, twice the riser plus the going between 550 and 700 mm, and 2 to 18 risers in a flight.

Total riseRiserGoingTotal run
Key Total rise divided into equal risers, with a going for each tread.
Units
Measure it. Take it from the finished floor below to the finished floor above, not to the joists. A typical storey is about 9 ft (US), 2.6 m (UK) or 2.7 m (AU), so the starting figure is only a placeholder.
m
mm

Used to pick the number of risers. Not a code figure.

mm

Leave blank to work it out.

m
Number of risers15 risers (14 treads)
Riser height180 mm
Going (tread depth)250 mm
Total run3.5 m
Stringer length4.42 m
Angle35.8°
Rule checkWithin the limits

2.7 m ÷ 180 mm target = 15, rounded to 15 risers. Riser: 2.7 m ÷ 15 = 180 mm. Treads: 15 − 1 = 14, so the run is 14 × 250 mm = 3.5 m. Angle: arctan(riser ÷ going) = 35.8°. Stringer: √(rise² + run²) = 4.42 m. 2 × riser + going = 610 mm.

Rise, going and angle only. Headroom, handrails, landings and winders have their own rules, and local amendments can be stricter.

Fig. 1 Risers, going and angle for your stairs.

Every formula is tested against worked examples. How we check

RisersRiser heightWithin the limits?
13207.7 mmNo
14192.9 mmNo
15180 mmYes
16168.8 mmYes
17158.8 mmYes

Fig. 2 The same height with one or two more or fewer risers.

Last checked 10/11/2026. Sources: NCC 2022 Housing Provisions, Part 11.2 Stairway and ramp construction (Table 11.2.2a).

Guide

How the calculator works

Take a 2.7 m floor-to-floor height and a target riser of 180 mm. 2,700 ÷ 180 = 15, so 15 risers of exactly 180 mm. A flight with 15 risers has 14 treads. At a 250 mm going the run is 14 × 250 = 3.5 m. The stringer is √(2.7² + 3.5²) = 4.42 m and the angle is 35.8°. Twice the riser plus the going is 2 × 180 + 250 = 610 mm, inside 550 to 700 mm.

You can type your own number of risers instead. With 14 risers each is 192.9 mm, over the 190 mm limit, so the calculator marks it as outside the limits.

The rules it checks, and where they come from

Table 11.2.2a of the NCC 2022 Housing Provisions gives a riser of 115 to 190 mm, a going of 240 to 355 mm, and 2R + G of 550 to 700 mm. A flight has 2 to 18 risers. Risers and goings count as constant if adjacent ones differ by no more than 5 mm and the largest and smallest in a flight differ by no more than 10 mm. A riser may not have an opening that lets a 125 mm sphere through. Headroom has its own rule in the NCC. Source: the ABCB page linked below.

These limits are for houses (Class 1 and 10 buildings). Other building classes and spiral stairs have different limits. Check your state variations and local rules.

A tight space

If space is short, a shorter going is tempting. At 230 mm the run falls to 3.22 m, but 230 mm is under the 240 mm minimum and the calculator flags it. Put your space in the optional box and it tells you whether the run fits and by how much.

What it does not check

  • Headroom above the stairs, handrail and guard heights, landings, winders and tapered treads, which all have their own rules.
  • Structure: stringer size and spacing, fixings and the floor above. Ask a builder or engineer.
  • Local amendments. Councils and states can be stricter than the national or model code, and a permit or inspection may be needed.
  • Existing stairs. Old houses are sometimes allowed to differ; ask your building authority.

Common questions

What riser should I aim for?

The NCC gives a range, not a target. Many people aim for 170 to 180 mm. Use the target box to try values.

Does the top step count as a tread?

No. A flight has one fewer tread than risers because the floor above is the last step. The calculator uses that.

Do I need approval for new stairs?

Usually, as part of a building approval. Ask your council or a private certifier.

How much can steps differ?

The NCC treats risers as constant if adjacent ones differ by no more than 5 mm and the largest and smallest in a flight differ by no more than 10 mm. The calculator divides the height into equal risers.